I've used 200 amp panels fed from a 100 amp feeder just for more spaces. $214.00 . 100A main breaker enclosed load center. Eaton PRL2A3100X18C Panel Board, PRL2A Interior, 100A, 480Y/277VAC, 18 Circuits Panelboard Interior, 100 Amp, 480Y/277V AC, 4-Wire, 3-Phase, 14 kAIC, 18-Space, 18-Circuits, Copper Bus, Breaker Type: GHB. I would run the 6/3 cable w/ground through the basement ceiling and through sill box into garage so it’s all indoor wiring. Main Breaker/Lug Provision on the Top of the Interior, Feed-Through Provision on Bottom of Interior. Typical application for a double pole 100 Amp breaker include feeding a sub panel device such as a 16 circuit 125A Stab-lok sub panel. I was just offering all the possibilities that came running thru my head with your original question .. if you are pulling this in conduit you cannot use any made up cable (NM , UF) .,. Location Olathe, Kansas . Trim mounting tabs free up both hands to drive trim screws. Add To List … seems to a lot of confusion over this one i marked for being under sized and refereed it to a electrician, builder refused and sent it was Ok under Article 310-15-B6 NEC #4 awg Buyer want it changed on his report An inspection and permit for your subpanel will ensure that you don’t have any insurance or liability issues. If your incoming power line cannot handle 200 amps, you could install a 100 amp main breaker to keep the power company happy but put in the 200 amp breaker panel, so in the future a main line upgrade could be done … General Electric Kit K-8015 Our Price: $149.95 . Trim mounting tabs free up both hands to drive trim screws. Use Current Location. Compare Click to add item "GE PowerMark Gold 100-Amp 18-Circuit 3-Phase Top Feed Indoor Main Breaker Load Center" to the compare list. Our Price: $149.95 . Free shipping ~NEW~ SQUARE D QO330L200G THREE PHASE 200 AMP MLO PANEL W/S COVER. Any help on this matter will be greatly appreciated.. Shipping Dimensions: … Item #177529 Model #W0202MB1100CU. main amps) NOTE: For I-LINE panels, upon selecting a Feed-thru lug kit (SL frame), you must enter the upstream disconnect if the application is Main Lug and Fully Rated. This 100 amp breaker in question does not pass the … With a main service disconnect off, the only power available will be uninteruptible utility power (no shutoff means available - other than pulling the meter). Siemens / GE / Square D / Cutler Hammer / Westinghouse / Thomas & Betts / Challenger / Crouse-Hinds Feed Through Panel Kit K-9010 - 125 Amp & Down Our Price: $149.95 . 5 out of 5 stars (1) 1 product ratings - ~NEW~ SQUARE D QO330L200G THREE PHASE 200 AMP MLO PANEL W/S COVER. #1 XHHW-2 Wire for 100 Amp Sub-Panel. My question is there are about 12 extra slots in this panel can I put my 100 amp disconnect breaker in this panel. I went from the meter base through 2 inch conduit on the outside of a building up to the attic through the attic without conduit and then down to the 100 amp service panel in conduit. This Kit mounts to Siemens, GE, Square D, Cutler Hammer, Thomas & Betts, Challenger, Crouse-Hinds, and … I have 2-15 amp circuits that currently feed … Subsequent steps in the P Series offer increased capacity and more design options: •The highly flexible P2 provides options to fit the most demanding specifications. If you have two 100 amp breakers in tandum at the head of your panel, yes, you will have a 200 amp service if you have 200 amps going in from your utility pole. Years ago tandom breakers had dual switches usually because of adding sub-panels for only 120 voltage needs. An opportunity for a story! The main is about 35 feet from where I would locate the sub-panel inside garage wall. It was found later that this adds potential dangers for overloading one side of a 240 amp circuit … Get Pricing and Availability . So you can use a 200 amp rated panel with a 100 amp main breaker for it, as long as the sub feeder is rated for 100 amps also. MPF designs and manufactures UHV power feedthroughs for scientific and harsh environments. Be sure to enter the proper ampacity when selecting the "SL" frame (e.g. GE PowerMark Gold 100-Amp 18-Circuit 3-Phase Top Feed Indoor Main Breaker Load Center. 100 Amp, 24 Spaces 48 Circuits Maximum QwikPak Panel Package with Breakers Square D Panel Packages combine a service entrance main breaker loadcentre and a selection of QO circuit breakers in a convenient package for quick installation. Tutorial outlining the step-by-step procedure for how to install a 225 A feed-through lug kit (part numbers: NQFTL2L and NQFTL2H) into an NQ Panelboard. Two (2) SEC panels are side by side, both with 200 amp main breakers. Oh my. OVERVIEW. Square D Kit K-5110 (QO & Homeline 100 Amp Main) Square D Feed Through Panel Kit K-9110 Square D Kit K-5210 Square D Kit K-5410 Our Price: … 2-2-2 Ramapo Triplex Underground Secondary Distribution Cable for 100 Amp Sub-Panel. Electrical Product Type: Mounting Type: Load center width (in.) Updating service panel to 200 amp with feeder to 100 amp panel in old house [ 8 Answers ] I currently in the process of converting 1000 sq ft of attached garage into living space while doing this we are updating electrical service to 200 amp new service, there is 100 amp service in the old part of the house which will remain but need to be sub paneled from the new 200 amp service. J. John120/240 Senior Member. I have 200 amp service to my home at an outside panel that feeds into the home. (Is this correct to use on a circuit feeding a 200 Amp main breaker?) … This breaker will work only in Federal Pioneer Stab-lok branded residential panels. Increasing distribution is simplified by the ability to add feed-thru lugs. Install the feed-through lugs included in the kit onto the ends of the panel bus bars, opposite the mains end, using the 1/4-20 x 7/8-inch tapping screws included in the kit. Tip: Check your local building codes to see if you need to submit special paperwork or if you need to acquire a permit to add … Installing a 200 amp Service Line. $67.95. 100 Amp Main Breaker Kit, for PRL2A, Top or Bottom Feed, Single or Three Phase, Breaker Type: FD, 35 kAIC, 480V AC, Wire Range: # 14 - 1/0. Square D … E. The left panel has a GEC wire of #4 AWG connected from that panel’s neutral/ground buss, which went back to the meter base panel (A).